Tealon

Tealon TF1570 | Blue

Tealon TF1570 is filled with glass microspheres and is suitable for aggressive chemical applications. It meets FDA conformance for service within food and pharmaceutical applications. TF1570 is the preferred material for fragile flanges, glass lined equipament or other applications that require higher compressibility.

Approvals: TA-Luft — FDA — Blow-Out — ABS — EU 1935/2004 — Germanischer Lloyd

1570

Tealon TF1580 | White

Tealon TF1580 (White) is filled with barium sulfate and is suitable for strong caustic fluids. It meets FDA conformance for service within food and pharmaceutical applications. 1580 can be used in a wide range of applications due to its vast resistance to most chemical products. It is compatible with strong acids along with strong caustics, making it the most diverse material within the Tealon family. With the white color of 1580, this material is also suitable for processes where contamination is not tolerated. Tealon 1580 meets and has been approved by BAM for oxygen service.

Approvals: DVGW — TA-Luft — FDA — BAM — Chlorine Institute — Blow-Out — ABS — EU 1935/2004 — Germanischer Lloyd

1580

Tealon TF1590 | Fawn

Tealon TF1590 (Fawn) is filled with silica and meets a wide range of aplications. It is suitable for general service, strong acids and moderate caustic solutions. It meets FDA conformance for service within food and pharmaceutical applications. TF1590 has easily passed the Hot Compression Test with outstanding results.

Approvals: DVGW — TA-Luft — FDA — Chlorine Institute — Blow-Out — ABS — EU 1935/2004 — Germanischer Lloyd — BAM — W270 — Air Liquide

1590

Hot Compression Test

This performance test measures the behavior of rPTFE and PTFE gaskets in a real world environment. The chart below shows a comparison between conventionally skived PTFE and Tealon. The gaskets we tested simulated a real world application including thermo-cycling. The skived PTFE gasket showed a very high leak rate, losing 60% of its initial pressure by the end of the test.

The Tealon gasket lost only 6% of its initial pressure by the end of the test and showed a leak 10 times less than that of the skived PTFE gasket. The pictures below, show the gaskets after the test and exhibit the dimensional stability of Tealon as compared to the noticeable creep of the skived PTFE gasket.

tealon teste

Thermo-Cycling Leak Test

Temperature cycles from 30ºC to 200ºC, with seating stress of 5000psi and using a gasket thickness of 1/8".

graftealon

Thermo-Cycling Leak Test Condition

Operating ParametersTF1570TF1580TF1590
Temperature -268 to 260 ºC
Max. Pressure 55 bar (800 psig) 83 bar (1200 psig) 83 bar (1200 psig)
Pressure x Temperature - bar x ºC Thickness 1/16" 12.000
Thickness 1/8" 8.600
Sheet Size 1500 mm x 1500 mm
Availability 0,5 mm up to 3,2 mm
Composition PTFE with glass microspheres PTFE with barium sulfate PTFE with silica
Physical PropertyType of TestTF1570TF1580TF1590
Color Blue White Fawn
Sealability (ml/h) ASTM F 37A 0.12 0.04 0.20
Creep Relaxation (%) ASTM F 38 40 24 18
Compressibility(%) ASTM F 36A 30-50 4-10 5-15
Recovery Min. (%) ASTM F 36A 30 40 40
Tensile Strength (MPa) ASTM F 152 14 14 14
"m" and "y" factor
Product Thickness
(mm)
"m" "y" (psi)
TF1570 1.5 2 1,500
3 2 1,500
TF1580 1.5 2 1,800
3 2 1,500
TF1590 1.5 4.4 2,500
3 3.5 2,000

ASTM tests are based on 1/32" sheet thickness.

 

Datasheet TF1570

Datasheet TF1580

Datasheet TF1590

 

 

 

TEADIT® Deutschland GmbH

Schanzenstraße 35, 51063 Köln, Germany

Phone: +49 (0)221/922 342-0

Fax: +49 (0)221/922 342-22

TEADIT® International Produktions GmbH

Rosenheimer Str. 10, A-6330 Kufstein Austria

Phone: +43-5372-64020-0

Fax: +43-5372-64020-20

 

2016 © Teadit | All Material Copyright are reserved.

 

This website uses modern technologies such as JavaScript, CSS, HTML5 and WebFonts; because of this, it is best viewed in modern browsers.

We recommend to use Google Chrome as your primary browser for this website.